This lock serialized all requests and made the inventory throttling in WebFetch redundant.
By moving this lock, two simultaneous requests may now take place which may help with http://opensimulator.org/mantis/view.php?id=7054
Move the experimental extra features functionality into the GridService. This sends default values for map, search and destination guide, plus ExportSupported control to the region on startup. Please watch http://opensimulator.org/wiki/SimulatorFeatures_Extras for changes and documentation.
This gives a count of all requests made to the remote inventory service.
This is finer grained than inventory.httpfetch.ProcessedFetchInventoryRequests since such a request can be comprised of many individual inv service calls.
In addition, this will count requests that don't go through the HTTP inventory fetch (e.g. HG, archiving, etc.)
This is for testing purposes (chiefly http://opensimulator.org/mantis/view.php?id=7054) so many not be permanent
Setting this will change the xinventory request timeout from the simulator from the default 100 seconds
Previously we used a heuristic of checking if the entry position is 0 to differentiate between Teleport and Cross, but that doesn't work anymore since we've started providing the precise entry position for cross, too. That's required in order to ensure that the user is allowed to enter the parcel that he's walking into.
For a long time, possibly forever, the m_maxAssetRequestConcurrency was mistakenly passed in as a 30 ms timeout rather than as a concurrent connection limiter.
This didn't come to light until the timeout was actually used in recent commit faf9ba53
Since this hasn't been operational for a long time and in release candidate phase, commenting it out for now though will need to revisit this.
Relates to http://opensimulator.org/mantis/view.php?id=7165
This can affect which region to use. E.g., returning users may be allowed to enter any region, whereas users from other grids will have to enter a gateway region. Previously per-user decisions were only made later, but by then it's too late to change which region the user enters.
This is actually code from commits afb2e07 and cf61cdf
For as yet unexplained reasons, the section of these commits which changed UserAgentServiceConnector.cs disappeared from its history between approx Feb 5 2014 and Feb 13 2014.
This ought to be impossible. More details to follow in opensim-dev mailing list
Conflicts:
OpenSim/Region/CoreModules/Framework/EntityTransfer/EntityTransferModule.cs
OpenSim/Region/Framework/Scenes/SceneBase.cs
OpenSim/Services/Interfaces/IGridService.cs
OpenSim/Services/LLLoginService/LLLoginResponse.cs
(conflicts were debug statements that are commented out in master branch)
CorssRegion, TeleportFinishEvent).
Have Simian grid service return the region size.
Many teleport related debug log messages. Can be removed when teleport
works (like that's ever going to happen).
Conflicts:
OpenSim/Framework/RegionInfo.cs
CorssRegion, TeleportFinishEvent).
Have Simian grid service return the region size.
Many teleport related debug log messages. Can be removed when teleport
works (like that's ever going to happen).
Rename 'RegionWorldLocX' to 'WorldLocX' and same for Y and Z.
This keeps the downward compatibility and follows the scheme of 'region'
and 'world' location naming that is happening in the Util module.